Battery Naming Rules

Battery Naming Rules

LPBF / LPBA / FLA / FLS → Stand for low-voltage battery packs

FLB → Stands for low-voltage waterproof battery packs (outdoor series)

FLH → Stands for high-voltage battery packs

FLS
FLS48100SCG1
Represents a low-voltage battery pack
48
FLS48100SCG1
Indicates the battery voltage. Expressed with two digits:
• 12 = 12.8V
• 24 = 25.6V
• 48 = 51.2V
100
FLS48100SCG1
Shows the battery capacity (Ah).
• 050 = 50Ah
• 100 = 100Ah
S
FLS48100SCG1
Specifies the battery pack model type, expressed by letters/numbers:
• S = Stacking
• W = Wall-mounted
• U = Plug-in box
• T = Tower
• B = Base
• R = Rack (followed by a number showing the number of layers)
• E = Cabinet
C
FLS48100SCG1
Represents the identification code:
• C = Primary control
• M = Expansion control
• Blank = No code
G1
FLS48100SCG1
Shows the version number:
• G1 = First version
• G2 = Second version
• and so on.

Battery

Inverter Naming Rules

Inverter Naming Rules

IVEM / IVCM→ High-frequency off-grid inverter

IVPM→ Industrial-frequency inverter with MPPT

IVPS→ Industrial-frequency inverter without MPPT

IVGM→ Hybrid inverter

IVPM
IVPM10048P1G2
Industrial-frequency inverter with MPPT.
100
IVPM10048P1G2
Inverter power, expressed in watts.
• 100 = 10,000W
• 150 = 15,000W
48
IVPM10048P1G2
Battery voltage.
• 12 = 12V
• 24 = 24V
• 48 = 48V
P1
IVPM10048P1G2
AC side phase type.
• P1 = Single phase
• P2 = Split phase
• P3 = Three phase
G2
IVPM10048P1G2
Version number.
• G1 = First version
• G2 = Second version
• And so on

IVGM

IVGM
IVGM8KLP2G2-EU
Hybrid inverter.
8K
IVGM8KLP2G2-EU
Inverter power.
• 8K = 8,000W
• 20K = 20,000W
L
IVGM8KLP2G2-EU
Battery voltage type.
• L = Low voltage (48V)
• H = High voltage (≥96V)
P2
IVGM8KLP2G2-EU
AC phase type.
• P1 = Single phase
• P2 = Split phase
• P3 = Three phase
G2
IVGM8KLP2G2-EU
Version number.
• G1 = First version
• G2 = Second version
• And so on
EU
IVGM8KLP2G2-EU
Product management code.
• EU = European version (US=American version)
• (Other codes may be added for different markets)

Inverter

IVGM

MPPT Controller Naming Rules

MPPT Controller Naming Rules

SCCM:stands for MPPT controller

SCCM
SCCM12048-III
MPPT controller.
120
SCCM12048-III
Maximum charging current.
• 150 = 150A
• 300 = 300A
48
SCCM12048-III
Compatible battery voltage.
• 12 = 12V
• 24 = 24V
• 48 = 48V
III
SCCM12048-III
Version number.
• I = First version
• II = Second version
• III = Third version